seriesBl2600 multi function computer This series is available in two models: with or without Ethernet, 44.2 MHz or 29.4 MHz RABBIT3000 microprocessor, and memory card with or without XD reader...
Rabbit is a brand of digi international
|
BL2600
|
BL2610
|
microprocessor
|
Rabbit3000@44.2 MHz
|
Rabbit3000@29.4 MHz
|
Ethernet port
|
10 / 100 baset, RJ-45, 3 LEDs
|
No,
|
Flash Memory
|
512KB standard
|
NAND flash memory
|
No,
|
SRAM memory
|
512KB standard
+256Kb SRAM (data)
|
512KB standard
|
SD memory
|
No,
|
Spare battery
|
Panasonic CR2477 or equivalent 3V lithium button battery
950mah, rack mount, RTC and SRAM backup
|
LED indicator
|
4 user programmable LEDs
|
Digital I / O
Configurable
|
16: Software can be configured separately, + / - 36VDC (rated threshold + 1.5V)
or Maximum 40V, 200mA digital output
|
Digital input
|
16: It can be configured by up and down jumpers, + / - 36VDC (rated threshold + 1.4V)
|
Digital power output
|
4: It can be configured separately through 40VDC software,
2A maximum value of each channel in procurement or precipitation mode
|
Analog input
|
8-channel 11 bit resolution. Software selection range:
Unipolar: 1, 2, 2.5, 5, 10, 20 VDC bipolar: + / - 1, + / - 2, + / - 5, + / - 10 VDC
4 channels (8 channels in total), software configurable, 4-20 mA, 12 kHz sampling
|
Analog output
|
4-channel 12 bit resolution, 0-10vdc, + / - 10VDC and 4-20mA, 12khz sampling
|
Serial port
|
Up to 5 serial ports:
-1 RS485 or RS232
-Two 3-wire RS232 or one RS232 with CTS / RTS
-One synchronous multiplexing to two RS422 SPI main ports (rabbitnet ports)
-1 dedicated CMOS compatible port programming / debugging
|
Serial speed
|
Maximum asynchronous mode speed = Clk / 8
Maximum speed synchronization mode = Clk / 2
|
Real time clock
|
Yes, sir.
|
timer
|
10 8-bit timers (6 can start from the first timer), 1 10 bit timer with 2 registers matching
|
Watchdog / Supervisor
|
Yes, sir.
|
Power Supply
|
9-36 VDC, maximum 25W (using power output and rabbitnet interface)
|
Service temperature
|
-40 ° C to + 70 ° C (- 40 ° C to + 85 ° C, no backup battery)
|
humidity
|
5% to 95% non condensing
|
Connector
|
-One Ethernet connector and two rabbitnet connectors in RJ45
-Two 9-point polarization connectors, not more than 2.54 mm (Molex type)
-Three 4-point power connectors, not more than 3.96 mm (Molex type)
-Two 20 point connectors, non-2.54 mm (with IDC 2x20 male connector)
-One 13 point connector with spacing of 2.54 mm (with IDC 2x13 male connector)
-One 10 point connector with spacing of 2.54 mm (with IDC 2x7 male connector)
-One IDC 2 x 5 programming port with spacing of 1.27mm (bl2600) or 2mm (bl2610)
|
size
|
123 mm x 126 mm x 25 mm
|